Lateral flow assay for simultaneous detection of cellular- and humoral immune responses
| Author | |
|---|---|
| Abstract |
OBJECTIVE: The development of a cytokine detection assay suitable for detection of multiple biomarkers for improved diagnosis of mycobacterial diseases. DESIGN AND METHODS: A lateral flow (LF) assay to detect IL-10 was developed utilizing the up-converting phosphor (UCP) reporter-technology. The assay was evaluated using blood samples of leprosy patients. Multiplex applications were explored targeting: 1) IL-10 and IFN-γ in assay buffer; 2) IL-10 and anti-phenolic glycolipid (PGL-I) antibodies in serum from leprosy patients. RESULTS: Detection of IL-10 below the targeted level of 100pg/mL in serum was shown. Comparison with ELISA showed a quantitative correlation with R(2) value of 0.92. Multiplexing of cytokines and simultaneous detection of cytokine and antibody was demonstrated. CONCLUSIONS: The UCP-LF IL-10 assay is a user-friendly, rapid alternative for IL-10 ELISAs, suitable for multiplex detection of different cytokines and can be merged with antibody-detection assays to simultaneously detect cellular- and humoral immunity. |
| Year of Publication |
2011
|
| Journal |
Clinical biochemistry
|
| Volume |
44
|
| Issue |
14-15
|
| Number of Pages |
1241-6
|
| Date Published |
10/2011
|
| ISSN Number |
1873-2933
|
| DOI |
10.1016/j.clinbiochem.2011.06.983
|
| Alternate Journal |
Clin Biochem
|
| PMCID |
PMC3177995
|
| PMID |
21763300
|
| Download citation | |
| Reactivity |
Human
|
| Category |
ELISA
|
| Analyte | IL-10
|